Measurement value, control module connections, seat control module (357k/Dk)
|
Measurement value, control module connections, seat control module (357k/Dk)
|
The following pages contain instructions and readings for testing the control module.
•
|
Observe the test criteria. Use common sense when assessing the test results.
|
•
|
The specified test readings are with the ignition ON, unless otherwise stated.
|
|
-
|
First check that the control module is supplied with current and is grounded.
|
|
-
|
Then check all sensor inputs and signals from other systems.
|
|
-
|
Finally, check the control module outputs. Remember that the test readings do not indicate whether the actuator is working.
|
•
|
If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.
|
•
|
The test readings given apply to a calibrated Fluke 88/97.
|
•
|
The test readings show the signal pulse condition or pulse length. A test instrument with pulse rate or width measurement must be used.
|
Note
|
All units on the I and P-buses send signals.
|
Number of connector pins
|
64
|
Pin
|
Component/function
|
In/Out
|
Test conditions
|
Measure across
|
Test reading
|
1-3
|
Not connected
|
|
|
|
|
4
|
Button, backrest forward
|
In
|
|
4-59
|
B+
|
5
|
Button, backrest backward
|
In
|
|
5-59
|
B+
|
6
|
Not connected
|
|
|
|
|
7
|
Memory button 3
|
In
|
|
7-59
|
B+
|
8
|
Memory button 1
|
In
|
|
8-59
|
B+
|
9
|
Memory button 2
|
In
|
|
9-59
|
B+
|
10
|
Memory store button
|
In
|
|
10-59
|
B+
|
11
|
Button, seat forward
|
In
|
|
11-59
|
B+
|
12
|
CV:
Microswitch, access handle
4D:
Not connected
|
In
|
Activated
|
12-58
|
B+
|
13
|
CV:
Microswitch, backrest
4D:
Not connected
|
In
|
Activated (forward-folded position)
|
13-58
|
B+
|
14
|
Button, seat backward
|
Out
|
|
14-59
|
B+
|
15
|
Button, tilt forward
|
Out
|
|
15-59
|
B+
|
16
|
Button, rear down
|
Out
|
|
16-59
|
B+
|
17
|
Button, rear up
|
Out
|
|
17-59
|
B+
|
18
|
Button, tilt back
|
Out
|
|
18-59
|
B+
|
19-26
|
Not connected
|
|
|
|
|
27
|
CV:
Power supply microswitch, backrest
4D:
Not connected
|
Out
|
|
27-58
|
B+
|
28
|
CV:
Power supply microswitch, access handle
4D:
Not connected
|
Out
|
|
28-58
|
B+
|
29
|
Power supply, hall sensor
|
In
|
Motor runs forward or backward
|
29-33
|
7.5-8.5V
|
30
|
Ground, hall sensor, tilt
|
In
|
Motor runs up or down
|
30-29
|
7.5-8.5V
|
31
|
Ground, hall sensor/backrest forward-backward
|
In
|
Motor runs forward or backward
|
31-29
|
7.5-8.5V
|
32
|
Ground, hall sensor/rear up-down
|
In
|
Motor runs up or down
|
32-29
|
7.5-8.5V
|
33
|
Ground, hall sensor/seat forward-backward
|
In
|
Motor runs forward or backward
|
33-29
|
7.5-8.5V
|
34-38
|
Not connected
|
|
|
|
|
39
|
I-bus
|
In/Out
|
Test lamp
|
39-58
|
Test lamp should flash*
|
40-53
|
Not connected
|
|
|
|
|
54
|
Motor, backrest
|
In/Out
|
|
54-55
|
3.8V
|
55
|
Motor, backrest
|
In/Out
|
|
55-58
|
3.8V
|
56
|
Not connected
|
|
|
|
|
57
|
Motor, tilt
|
In/Out
|
|
57-58
|
3.5V
|
58
|
Ground
|
In
|
|
58-59
|
B+
|
59
|
+30 voltage
|
In
|
|
59-58
|
B+
|
60
|
Motor, group 1
|
In/Out
|
|
60-58
|
3.5V
|
61
|
Not connected
|
|
|
|
|
62
|
Motor, rear height adjustment
|
In/Out
|
|
62-58
|
3.5V
|
63
|
CV:
Motor, access
4D:
Not connected
|
In/Out
|
|
63-58
|
3.5V
|
64
|
Motor, legroom adjustment
|
In/Out
|
|
64-58
|
3.5V
|
*All control modules send a voltage