RDCM / C0800 03
Read the instructions below then start the fault diagnostic procedure.
Symptom: Message appears in display.
C0800 03 |
Fault symptom
Message appears in display.On-board diagnosis
Type of diagnosis:
Continuous |
Enable criteria:
Ignition ON. |
Fault criteria:
The control module power supply falls below 8.5V for more than 25 s. |
System reaction to a fault:
Rear wheel drive shut down |
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |