STC / B1010 08
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Possible message on the display
Soft top cannot be operated
Position Sensor, Invalid Position

Fault symptom
Possible message on the display
Soft top cannot be operated
On-board diagnosis
Type of diagnosis:
Enable criteria:
Soft top opening/closing activated |
Fault criteria:
One of the position sensors is incorrectly positioned in comparison with the other position sensors. |
System reaction to a fault:
Control module switches off soft top operation |
Diagnostic help
Diagnosis regards:
The soft top is operated in sequences. Each sequence must begin with the sensors in a position that matches the movement pattern. |
Functions in the diagnostic tool related to the fault:
• | Tonneau Cover Latched Left |
• | Tonneau Cover Latched Right |
(See also description of readings/activations in diagnostic tool) |