SAAB WIS ONLINE

STC / B3602 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Soft top cannot be operated Message appears in display.

  B3602 02


Soft Top Switch Circuit, Short to Ground

Fault symptom

Soft top cannot be operated

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Control module input voltage is below 1.3V ±0.2V.

Dependent:

The following diagnostic trouble codes may not be generated:
B1423

System reaction to a fault:

In case of a fault, the control module will ignore button presses.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Soft Top Motion Request
(See also description of readings/activations in diagnostic tool)