SAAB WIS ONLINE

UHP / U2100 00

Read the instructions below then start the fault diagnostic procedure.

  U2100 00


UHP was Missing on Bus



On-board diagnosis

Enable criteria:

Call/Voice control must not be active.

Fault criteria:

Control module absent on the I-bus.

Checking the wiring harness

Jiggle the wiring harness at several points to detect intermittent breaks or short circuits. Check also the connector for oxidation or loose pins.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or in the component (mainly poor contact).
During the response test, move the wiring harness to check that no bus lead/power supply or ground lead fault exists. In addition, check the condition of the connector and the pins.

Functions in the diagnostic tool related to the fault:

Operation
Response test, under "All/Bus" menu.