Relay unit, radiator fan (706a), with two radiator fans, E39
| Relay unit, radiator fan (706a), with two radiator fans, E39 |
| Connection |
| 706a pin no | Signal type | Description |
| 3 | BATT+ | Powered from maxi fuse 36 to pin 3. |
| 6 | BATT+ | Powered from maxi fuse 35 to pin 6. |
| 2, 5 | ground | Grounded to grounding point G30A, via crimp connection J1. |
| 1, 4 and 7 | ground | Grounded by SCM (587). The pin is grounded differently depending on the current fan stage. |
Power supply and control