Relay unit, radiator fan (706a), with two radiator fans, E39
Relay unit, radiator fan (706a), with two radiator fans, E39 |
Connection |
706a pin no | Signal type | Description |
3 | BATT+ | Powered from maxi fuse 36 to pin 3. |
6 | BATT+ | Powered from maxi fuse 35 to pin 6. |
2, 5 | ground | Grounded to grounding point G30A, via crimp connection J1. |
1, 4 and 7 | ground | Grounded by SCM (587). The pin is grounded differently depending on the current fan stage. |