SAAB WIS ONLINE

Wiring harness, valve housing with temperature sensor

Wiring harness, valve housing with temperature sensor

To remove


1. Remove the Valve housing cover

2. Remove the Valve housing ..

3. Remove the control module.

Unplug the connector


Set the gear selector lever in position P and remove the nut (A) for the lever (B).


Engage position N and remove the lever.

Pull the gear cable sleeve (C) backwards and lift up the cable and move it aside.

Remove the control module screws x 3 (D).

Lift the control module off the shaft and connector. Lift straight up to avoid damaging the connector on the gearbox.

4. Remove the wiring harness.

Remove the circlip (A).


Lift out the wiring harness (B).


To fit


1. Fit the wiring harness.

Fit a new seal (B) in the gearcase and an O-ring on the connection (A).


2. Fit in the wiring harness (B).


Make sure that the connector's guide pin locates in the groove and fit the circlip (A).

3. Fit the control module.

Important

Counterhold the locking sector when the control module and lever are fitted.


Carefully press the control module straight and down towards the shaft and the connector.

Fit the control module screws (D).

Tightening torque 25 Nm (18 lbf ft)


Pull the gear cable sleeve (C) backwards and fit the cable in its bracket.

Fit the lever (B).

Engage position P and fit the nut (A).

Tightening torque 15 Nm (11 lbf ft)

Engage position N.

Plug in the connector.

4. Fit the Valve housing .

5. Fit the Valve housing cover .