SAAB WIS ONLINE

CIM / B1325 03

Read the instructions below then start the fault diagnostic procedure.

  B1325 03


Control Module, Supply Voltage Low



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
The diagnostic runs when another DTC is detected in the CIM.

Fault criteria:

The control module voltage supply is below 7.5 V at the same time as another DTC is detected in the CIM.

System reaction to a fault:

None

Checking the wiring harness

Jiggle the wiring harness at several points to detect intermittent breaks or short circuits. Check also the connector for oxidation or loose pins.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Battery Voltage
(See also description of readings/activations in diagnostic tool)