Read the instructions below then start the fault diagnostic procedure.

Symptom: Memory functions not working Tilt out of order. Manual electric mirror operation working.

  B1583 02


Mirror Potentiometer Supply Circuit, Short to Ground

Fault symptom

Memory functions not working

Tilt out of order.

Manual electric mirror operation working.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
The following DTCs are generated at the same time as this DTC:
B3355, B3832
NONE of the following DTCs must be detected:
B1585, B1595

Fault criteria:

Power supply below limit value.

System reaction to a fault:

Memory functions not working
Tilt out of order.
Manual electric mirror operation working.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Mirror Potentiometer Left/Right Driver Door
(See also description of readings/activations in diagnostic tool)