E39 / P0118 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
Radiator fan runs continuously.
No A/C function.
Engine Coolant Temperature Sensor Circuit. Short to B+ / Open circuit.
Fault symptom
Malfunction Indicator Lamp
Radiator fan runs continuously.
No A/C function.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Engine running more than 10 seconds. |
Fault criteria:
When the signal on the control module input corresponds to a temperature less than -60 °C for more than 5 seconds. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |