SAAB WIS ONLINE

E39 / P0135 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Malfunction Indicator Lamp

  P0135 00


O2S 1 Preheater Circuit Performance Problem

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

The following diagnostic trouble codes may not be generated:
P0116, P0117, P0118, P0119
P0128
Battery voltage should be between 10.7 and 18 Volts.
Engine running.

Fault criteria:

When the current across the sensor exceeds 2.5 A or is below 0.3 A for more than 60 seconds.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
O2S 1 Preheating

Activation:
O2S 1 Preheating

(See also description of readings/activations in diagnostic tool)