Read the instructions below then start the fault diagnostic procedure.

Symptom: The starter motor may function independently. Or No starter motor cranking.

  P0615 00


Starter Relay Circuit Malfunction

Fault symptom

The starter motor may function independently.

Or

No starter motor cranking.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10 - 18 V.

Fault criteria:

Open circuit or short circuit on the control module output

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Starter Relay