E39 / P0622 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Warning lamp lights.
Generator F Terminal Circuit, Function Failure
Fault symptom
Warning lamp lights.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Ignition on for at least 5 s. |
Engine running more than 20 seconds. |
Fault criteria:
When the PWM signal on the output is higher than 65%. |
When the PWM signal on the output is less than 5%. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Generator connection for field current (DF). Originates in the internal regulator and shows the amount of period length for which the generator applies field current. Used to calculate generator torque requirement. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |