Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE

  P0697 00


5V Supply Group 3, Short to Ground/B+

Fault symptom

CHECK ENGINE

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

When the 5-volt output to the following components short circuits to ground or B+:
Accelerator pedal position sensor
Manifold absolute pressure sensor

Dependent:


None

OK report:

Fault criteria NOT fulfilled.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force.

Diagnostic help

Diagnosis regards:


Functions in the diagnostic tool related to the fault:

Read values for the above components.
(See also description of readings/activations in diagnostic tool)