SAAB WIS ONLINE

E39 / P1682 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE Engine does not start. Engine shut off.

  P1682 00


Plausibility Fault between voltage feed from +15 and main relay

Fault symptom

CHECK ENGINE

Engine does not start.

Engine shut off.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Test 1
Ignition ON.

Test 2
When the ignition is switched off.

Fault criteria:


The voltage difference between the control module's pins A51/A70 and A73 is more than 3V.

Dependent:

None

System reaction to a fault:

None

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Diagnostic help

Diagnosis regards:

Finding electrical faults on the power supply from the main relay.

Functions in the diagnostic tool related to the fault:

Test value:
Main Relay
Main Relay Output
Ignition switch +15
Ignition Key Position
Battery Voltage:

Activation:
Main Relay
(See also description of readings/activations in diagnostic tool)