SAAB WIS ONLINE

E39 / P2067 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: D.T.E out or order.

  P2067 00


Fuel Level Sensor 2 Circuit, Short to Ground

Fault symptom

D.T.E out or order.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Engine running.

Fault criteria:


Input voltage below 0.25 V.

Dependent:

None

Fault handling:

Type III without Check Engine.
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Fuel Level
Fuel Level Sensor 2

(See also description of readings/activations in diagnostic tool)