Read the instructions below then start the fault diagnostic procedure.

Symptom: Malfunction Indicator Lamp

  P2119 00


Throttle, Return Spring Failure

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10 - 18 V.
Ignition ON.
The pedal position sensor position is lower than 15%.
Vehicle speed 0 km/h.

Fault criteria:

The throttle does not reach parked position in a predetermined time, 0.6 s from request.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.
Mechanically binding/affected throttle.

Functions in the diagnostic tool related to the fault:

Test value:
Throttle Position Sensor 1
Throttle Position Sensor 2

Activation:
Throttle Position

(See also description of readings/activations in diagnostic tool)