E39 / P2138 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
Performance loss.
Pedal Position Sensor Circuit. Plausibility Fault Between Circuit 1 and 2.
Fault symptom
Malfunction Indicator Lamp
Performance loss.
On-board diagnosis
Type of diagnosis:
Enable criteria:
The following diagnostic trouble codes may not be generated: |
Fault criteria:
When the voltage difference between pedal position sensor 1 and 2 is 8 - 10% depending on pedal position (8% released pedal, 10% fully engaged pedal). |
When the voltage for both sensors exceeds 5% of the learnt minimum value. |
System reaction to a fault:
OK report:
Fault criteria NOT fulfilled. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |