SAAB WIS ONLINE

E39 / P2176 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Malfunction Indicator Lamp

  P2176 00


Throttle Mechanical, Can Not Reach Closed Position

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10 - 18 V.
Ignition ON.

Fault criteria:

The signal from throttle position sensors is greater than expected during the learning process.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Throttle Position Sensor 1
Throttle Position Sensor 2

Activation:
Throttle Position

(See also description of readings/activations in diagnostic tool)