Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE Engine does not start.

  P0628 00


Fuel Pump Relay Control Circuit Low Voltage

Fault symptom

CHECK ENGINE

Engine does not start.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Ignition ON.
Output active.

Fault criteria:

When voltage on the output is below 2.0 V for more than 1 s.

Dependent:

None

System reaction to a fault:

SCM requests CHECK ENGINE lamp lit by ECM.

OK report:

Fault criteria NOT fulfilled for 2 s with engine running.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
Fuel Pump Relay
Test value:
Fuel Pump Relay
(See also description of readings/activations in diagnostic tool)