SAAB WIS ONLINE

SCM / P0693 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Radiator fan malfunction. No A/C function.

  P0693 00


Cooling Fan 2 Control Circuit, Open/Short to Ground

Fault symptom

Radiator fan malfunction.

No A/C function.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Engine running.
Output is not active.

Fault criteria:

When voltage on the output is below 2.0 V for more than 1 s.

OK report:

Fault criteria NOT fulfilled for 5 s.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Fan Control Output 2
Requested Fan Speed
Activation:
Fan Control Output SCM
(See also description of readings/activations in diagnostic tool)