SCM / P2537 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: None
+X, Open/Short to Ground
Fault symptom
None
On-board diagnosis
Type of diagnosis:
Enable criteria:
Ignition on for 2 s followed by engine running. |
Fault criteria:
No voltage on +X for 60 s when +15 is energized. |
Dependent:
System reaction to a fault:
OK report:
Fault criteria NOT fulfilled for 61 s. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |