SAAB WIS ONLINE

T8 / P2065 00

Read the instructions below then start the fault diagnostic procedure.

  P2065 00


Fuel Level Sensor 2 Circuit, Performance Problem



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10 - 18 V.
Engine running.

Fault criteria:

Fuel level sensor signal does not match the change in level corresponding to the amount of fuel consumed.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Fuel Level Sensor 2 (Left)

(See also description of readings/activations in diagnostic tool)