SAAB WIS ONLINE

TCM E39 / P0705 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Engine does not start.

  P0705 00


Transmission Range Switch. Input Incorrect.

Fault symptom

Engine does not start.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Turn Ignition On
Battery voltage must be between 9 - 18 V.

Fault criteria:

Total voltage of the two position sensors deviates by more than 0.29 V from the standard 5 V

System reaction to a fault:

Limp home

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Gear Selector Position
(See also description of readings/activations in diagnostic tool)