SAAB WIS ONLINE

TCM E39 / P0741 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display.

  P0741 00


Lock-up. Mechanical Fault.

Fault symptom

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10.2 - 15.5 V.
Engine speed less than 4000 rpm.
Oil temperature > -7 °C
Lock-up activated
Selector lever in position D.
TCM not in Limp Home
The following diagnostic trouble codes may not be generated:
P0715
P0717
P0720
P0722
P2761
P2763
P2764

Fault criteria:

TCM registers rapid speed changes on the output shaft or TCM registers a difference greater than 100 rpm between input shaft speed and engine rpm.

System reaction to a fault:

Excluded Lock-Up function.
Poor shifting quality.

Diagnostic help

Diagnosis regards:

Locating a mechanical fault.