TCM E39 / P0742 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
Lock-up. Mechanical Fault.
Fault symptom
Message appears in display.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 10.2 - 15.5 V. |
Engine speed between 1000 and 3000 rpm. |
Selector lever in position D. |
The following diagnostic trouble codes may not be generated: |
Fault criteria:
Difference between engine speed and input rpm is outside the limit value. |
System reaction to a fault:
Diagnostic help
Diagnosis regards:
Locating a mechanical fault. |