SAAB WIS ONLINE

TCM E39 / P0974 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display.

  P0974 00


Solenoid S1 Circuit, Open/Short to B+

Fault symptom

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

TCM not in Limp Home
Battery voltage must be between 10.2 - 15.5 V.
Engine speed over 400 rpm.
The diagnostic runs when the output is enabled.

Fault criteria:

Solenoid signal output is OFF but the input receives an ON signal.

System reaction to a fault:

Limp home

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
S1 Commanded Status
S1 Actual Status
Activation:
S1 Commanded Status
(See also description of readings/activations in diagnostic tool)