Liftgate Control Module Programming and Setup
|
Liftgate Control Module Programming and Setup
|
The following service procedures require either a programming or a setup event performed for a complete repair.
Liftgate Control Module Replacement
|
If the liftgate control module is replaced, the following procedures must be performed.
2.
|
Perform the SPS function Liftgate Control Module - Programming and follow the on-screen instructions.
|
3.
|
Perform the SPS function Liftgate Control Module - Configuration & Setup and follow the on-screen instructions. On the screen Control Module - Configuration & Setup Function(s), select both ECU Configuration/Reconfiguration and the appropriate ECU Setup.
|
4.
|
Clear DTCs after completing the programming procedure.
|
5.
|
Perform the Liftgate Calibration procedure and if needed, the Garage Height Calibration.
|
Liftgate Control Module Reprogramming
|
Do not reprogram the liftgate control module unless directed by a service procedure or a service bulletin.
2.
|
Perform the SPS function Liftgate Control Module - Programming and follow the on-screen instructions.
|
3.
|
Clear DTCs after completing the programming procedure.
|
4.
|
Perform the Liftgate Calibration procedure and if needed, the Garage Height Calibration.
|
If any portion of the power liftgate assembly is replaced, repaired or disassembled, perform the following liftgate calibration procedure:
1.
|
Connect the scan tool to the vehicle.
|
2.
|
Select the SPS function Diagnostics:
|
3.
|
Select Liftgate Control Module:
|
4.
|
Select Configuration & Setting:
|
5.
|
Select Liftgate Max. Opening Position Setting:
|
6.
|
Press "Enter" and follow the on-screen instructions:
|
Garage Height Calibration
|
If any portion of the power liftgate assembly is replaced, repaired or disassembled, perform the following liftgate calibration procedure:
1.
|
Ensure that the rotary switch on the driver door panel is set to Garage.
|
2.
|
Open the liftgate to the desired height manually or by using the one of the following switches:
|
|
•
|
The rotary switch on the overhead console
|
|
•
|
The unlatch switch on the liftgate handle
|
|
•
|
The remote control switch on the key fob
|
3.
|
Hold the shutface switch for at least 3 seconds with the liftgate at the desired height.
|
4.
|
Close the liftgate completely using one of the following switches:
|
|
•
|
The rotary switch on the overhead console
|
|
•
|
The shutface switch on the liftgate
|
|
•
|
The remote control switch on the key fob
|