Liftgate Module Scan Tool Data Parameters
Parameter
|
Expected Value
|
Description
|
Operating Conditions:
Ignition ON
|
In Park Switch Status
|
On/Off
|
The scan tool displays Off or On. On is displayed if the vehicle was in Park during the last open or close history data.
|
Liftgate Angle
|
0°
|
The scan tool displays the calculated angle in degrees of the liftgate relative to the liftgate latch.
|
Liftgate Front Control Switch
|
Active/Inactive
|
The scan tool displays Active or Inactive. This is the state of the front control switch of the liftgate module.
|
Liftgate Handle Switch
|
Active/Inactive
|
The scan tool displays Active or Inactive. This is the state of the liftgate handle switch.
|
Liftgate Mode Switch
|
Varies
|
The scan tool displays the current setting of the mode switch in Counts which varies depending upon if the switch is in the Off, 3/4 or Max position and the system voltage.
|
Liftgate Rear Close Switch
|
Active/Inactive
|
The scan tool displays Active or Inactive. This is the state of the liftgate shutface switch.
|
Liftgate Latch Pawl Switch
|
Active/Inactive
|
The scan tool displays Active or Inactive. This is the state of the latch pawl switch.
|
Liftgate Latch Ratchet Switch
|
Active/Inactive
|
The scan tool displays Active or Inactive. This is the state of the latch ratchet switch.
|
Liftgate Latch Sector Switch
|
Active/Inactive
|
The scan tool displays Active or Inactive. This is the state of the latch sector switch.
|
Liftgate System Voltage 1
|
11.5-13.0 V
|
The scan tool displays the battery system 1 voltage input to the liftgate module.
|
Liftgate System Voltage 2
|
11.5-13.0 V
|
The scan tool displays the battery system 2 voltage input to the liftgate module.
|
Secondary Obstacle Detection Liftgate
|
3-3.5 V
|