Air Conditioning (A/C) System Performance Test
|
Air Conditioning (A/C) System Performance Test
|
This test measures the operating efficiency of the A/C system under the following conditions:
•
|
The current ambient air temperature
|
•
|
The current relative humidity
|
•
|
The high side pressure of the A/C system
|
•
|
The low side pressure of the A/C system
|
•
|
The temperature of the air being discharged into the passenger compartment
|
Test Description
The numbers below refer to the step numbers on the diagnostic table.
1
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
2
This step measures the performance of the A/C system.
3
This step is to allow for vehicle variations as well as high ambient temperatures.
Step
|
Action
|
Values
|
Yes
|
No
|
Note
|
•
|
The ambient air temperature must be at least 16°C (60°F) .
|
•
|
Do not induce additional air flow across the front of the vehicle during the test.
|
•
|
If you were sent here from a DTC diagnostic table, clear the DTC upon completion of this test.
|
|
1
|
1.
|
Park the vehicle inside or in the shade.
|
2.
|
Open the windows in order to ventilate the interior of the vehicle.
|
3.
|
If the A/C system was operating, allow the A/C system to equalize for about 2 minutes.
|
4.
|
Turn OFF the ignition.
|
5.
|
Install the
J-43600
ACR 2000 Air Conditioning Service Center or
GE-48800
CoolTech A/C Recharge Machine
|
6.
|
Record the ambient air temperature and humidity.
|
7.
|
Record the low and high side STATIC pressure readings.
|
Are both the low side and high side pressures within the specified value?
|
More than 16°C (60°F) - 345 kPa (50 psi)
More than 24°C (75°F) - 483 kPa (70 psi)
More than 33°C (90°F) - 690 kPa (100 psi)
|
Go to
Step 2
|
Go to
Leak Testing
|
2
|
1.
|
Note
|
Record the relative humidity and the ambient air temperature at the time of the test.
|
Close the vehicle doors and windows.
|
2.
|
Open the drivers door window 12.7-15.2 cm (5-6 in).
|
3.
|
Select the following HVAC control settings:
|
|
•
|
The coldest temperature setting
|
|
•
|
The maximum blower speed
|
|
•
|
The instrument panel (I/P) outlet mode
|
|
•
|
All I/P outlets are OPEN.
|
4.
|
Install thermometers in the left and right center panel air outlets.
|
5.
|
Apply the parking brake.
|
6.
|
Place the transaxle/transmission in one of the following positions:
|
7.
|
Start the engine and warm to operating temperature.
|
8.
|
Operate the A/C system for 5 minutes.
|
9.
|
Inspect A/C components for the following conditions:
|
10.
|
Record the following information:
|
|
•
|
The panel outlet air temperatures
|
11.
|
Compare the low and high side pressures and the panel output temperatures to the A/C Performance Table below.
|
Does all the data recorded fall within the specified ranges of the A/C Performance Table below?
|
-
|
Go to
Step 5
|
Go to
Step 3
|
3
|
If the pressures and temperatures recorded do not fall within the specified ranges:
1.
|
Continue to operate the A/C system for an additional 5 minutes.
|
2.
|
Record the pressures and temperatures again.
|
3.
|
Compare the low and high side pressures and the panel output temperature to the A/C Performance Table below.
|
Does all the data recorded fall within the specified ranges of the A/C Performance Table below?
|
-
|
Go to
Step 5
|
Go to
Step 4
|
4
|
Perform the necessary repairs. Refer to
A/C Diagnostics Chart
.
Is the action complete?
|
-
|
Go to
Step 5
|
-
|
5
|
Operate the system in order to verify the test results.
Did you find the same results?
|
-
|
System OK
|
Go to
Symptoms - HVAC Systems - Automatic
|
A/C Performance Table
Ambient Temperature
|
Relative Humidity
|
Low Side Service Port Pressure
|
High Side Service Port Pressure
|
Maximum Left Center Discharge Air Temperature
|
13-18°C (55-65°F)
|
0-100%
|
175-200 kPa (25-30 psi)
|
500-850 kPa (70-125 psi)
|
5°C (40°F)
|
19-24°C (66-75°F)
|
Less than 40%
|
175-240 kPa (25-35 psi)
|
690-1100 kPa (100-160 psi)
|
5°C (40°F)
|
Greater than 40%
|
175-240 kPa (25-35 psi)
|
690-1100 kPa (100-160 psi)
|
7°C (45°F)
|
25-29°C (76-85°F)
|
Less than 35%
|
175-240 kPa (25-35 psi)
|
1000-1300 kPa (145-190 psi)
|
10°C (50°F)
|
35-60%
|
175-240 kPa (25-35 psi)
|
1000-1340 kPa (145-195 psi)
|
10°C (50°F)
|
Greater than 60%
|
175-280 kPa (25-40 psi)
|
1000-1370 kPa (145-200 psi)
|
10°C (50°F)
|
30-35°C (86-95°F)
|
Less than 30%
|
175-280 kPa (25-40 psi)
|
1240-1590 kPa (180-230 psi)
|
13°C (55°F)
|
30-50%
|
175-280 kPa (25-40 psi)
|
1240-1620 kPa (180-235 psi)
|
13°C (55°F)
|
Greater than 50%
|
175-280 kPa (25-40 psi)
|
1240-1650 kPa (180-240 psi)
|
13°C (55°F)
|
36-41°C (96-105°F)
|
Less than 20%
|
240-320 kPa (35-45 psi)
|
1500-1860 kPa (215-270 psi)
|
15°C (60°F)
|
20-40%
|
240-320 kPa (35-45 psi)
|
1500-1900 kPa (215-275 psi)
|
15°C (60°F)
|
Greater than 40%
|
240-320 kPa (35-45 psi)
|
1500-1900 kPa (215-275 psi)
|
15°C (60°F)
|
42-46°C (106-115°F)
|
Less than 20%
|
280-350 kPa (40-50 psi)
|
1765-2100 kPa (255-305 psi)
|
18°C (65°F)
|
Greater than 20%
|
280-350 kPa (40-50 psi)
|
1765-2100 kPa (255-305 psi)
|
18°C (65°F)
|
47-49°C (116-120°F)
|
Below 30%
|
320-380 kPa (45-55 psi)
|
2000-2240 kPa (290-325 psi)
|
20°C (70°F)
|