Refrigerant System Specifications
|
Refrigerant System Specifications
|
Refrigerant System Capacities
Application
|
Specification
|
Metric
|
English
|
Abrupt Refrigerant Loss
|
60 ml¹
|
2.0 oz¹
|
PAG Oil GM P/N 12378526 for United States
PAG Oil GM P/N 88900060 for Canada
|
Compressor Replacement
|
Note
|
Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.
|
The service compressor is shipped with 74 ml
2
(2.5 oz
2
) of PAG oil.
|
Condenser Replacement
|
30 ml
2
|
1.0 oz
2
|
Evaporator Replacement
|
90 ml
2
|
3.0 oz
2
|
Any Line Set (Hose/Tube or Tube Assembly) Replacement
|
30 ml
2
|
1.0 oz
2
|
•
|
Total System PAG Oil Capacity
|
|
110.0 ml
|
3.7 oz
|
R-134a
|
|
0.73 kg
|
1.61 lb
|
¹ Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component.
2
If more than the specified amount of PAG oil was drained from a component, add the amount drained.
|