Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE. Possible misfiring before diagnostic trouble code is generated.

P0134


O2S Circuit. No Activity Detected. Sensor 1.


Fault symptoms


CHECK ENGINE.

Possible misfiring before diagnostic trouble code is generated.


On-Board Diagnostics

Type of diagnosis:


- Continuous. However, it is interrupted once the fault criteria have been fulfilled and does not restart until the next driving cycle.


Enable criteria: (Conditions that must be fulfilled for diagnostics to be performed.)


- Engine running. Main relay voltage exceeding 10v. Preheating has been active for more than 8 min.


Fault criteria: (When enable criteria have been fulfilled, diagnostics will check if the fault criteria have been fulfilled.)


- Test 1: Voltage has not been outside the range 0.400- 0.600 V.

- Test 2: Closed loop active and voltage has not been outside the range 0.400-0.600 V for 10s.


Dependents: (Once fault criteria have been fulfilled, a number of other diagnostics must report OK before the diagnostic trouble code can finally be generated.)


- P1135 and P1136


System reaction to a fault: (Once the fault criteria have been fulfilled, certain measures will sometimes be taken.)


- Closed loop control system blocked.


OK report: (This diagnosis may be included as a dependent to another diagnosis and must therefore report OK even if it is continuous. The OK report is also used in fault handling to count down the fault counter.)


- Test 1 and Test 2 performed once and fault criteria not fulfilled. 60s has passed and closed loop is still active. Fault criteria for P0131 or P0132 not fulfilled.


Fault handling: (Refer to section “Fault diagnosis, general” for more information.)


- Type III.


Diagnostic help

Fault diagnosis concerns an electrical fault in the connecting leads or in the sensor.

Diagnostic tool functions related to this fault:


Diagnostic status for the diagnosis.

Oxygen sensor reading, unit V.


Refer also to the description of readings under ”Fault diagnosis, general” for more information

Note

The oxygen sensor receives reference oxygen from the surroundings via the connecting cables. For this reason, contact spray or grease must not be used on the oxygen sensor connector.


Check the wiring

Jiggle the wiring harness at several points and in different directions to check if there are intermittent breaks and short-circuits in the leads. Observe the multimeter, test lamp or diagnostic instrument during the test.

See .