P1659
Read the instructions below then start the fault diagnostic procedure.
Symptom: CHECK ENGINE.
P1659 |
Fault symptoms
• |
CHECK ENGINE.
|
On-Board Diagnostics
Type of diagnosis:- |
Continuous. However, it is interrupted once the fault criteria have been fulfilled and does not restart until the next driving cycle.
|
Enable criteria: (Conditions that must be fulfilled for diagnostics to be performed.)
- |
Engine running. Main relay voltage exceeding 10V. Output is active.
|
Fault criteria: (When enable criteria have been fulfilled, diagnostics will check if the fault criteria have been fulfilled.)
- |
Voltage on the output exceeding 2V for more than 1s.
|
Dependents: (Once fault criteria have been fulfilled, a number of other diagnostics must report OK before the diagnostic trouble code can finally be generated.)
- |
None.
|
System reaction to a fault: (Once the fault criteria have been fulfilled, certain measures will sometimes be taken.)
- |
None.
|
OK report: (This diagnosis may be included as a dependent to another diagnosis and must therefore report OK even if it is continuous. The OK report is also used in fault handling to count down the fault counter.)
- |
As for P1110: Enable criteria fulfilled and amplitude below 1 kPa. The criteria must be fulfilled on three consecutive occasions during the same driving cycle.
|
Fault handling: (Refer to section “Fault diagnosis, general” for more information.)
- |
Type III.
|
Diagnostic help
Fault diagnosis concerns an electrical fault in the connecting leads or in the valve.Diagnostic tool functions related to this fault:
• |
Activation of the output for the valve.
|