Fuel shut-off
Fuel shut-off |
• |
no power supply (+15 circuit)
|
• |
fully depressed accelerator pedal during starter motor cranking
|
• |
engine speed over 6200 rpm.
|
• |
air mass/combustion over 1100 mg/c
|
• |
incorrect immobilizer code
|
• |
throttle turned by hand when engine running
|
• |
serious fault in throttle valve control
|
• |
a pedal position sensor fault if engine speed exceeds 2200 rpm
|
• |
ignition discharge module not supplied with current
|
• |
engine speed above 1800 rpm and accelerator pedal completely released, and coolant temperature exceeding 20 °C. On manual gearboxes, this applies to 3rd, 4th and 5th gears. On cars with automatic transmission, this applies in 2nd, 3rd and 4th gears. Injection will restart at 1400 rpm.
|
Diagnostics |
If TWICE does not send out ”Immobilizer OFF” after the ignition has been switched on or if the Trionic T7, TWICE or MIU control modules are replaced and the immobilizer code is not programmed in TWICE, diagnostic trouble code P1460 will be generated and the engine cannot be started.