Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.

B1340


Solar Sensor. Open Circuit / Communication Fault


Fault symptoms

Perceived temperature in cabin too high or too low compared to the set temperature.

Conditions

The following conditions apply:


Open circuit or communication error.

The solar sensor sends an identification pulse continuously, 5V-0V-5V. The control module searches for identification pulses during time periods of 440 ms. When five successive measurements have been made with no pulse pattern, a DTC is generated.

The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.

When the diagnostic trouble code has been generated, the control module uses a default value, that being the latest valid value. When ignition is turned on, 0 W/m 2 .


Diagnostic help

Check that a value is obtained from all 5 directions.