SAAB WIS ONLINE

B2375

Read the instructions below then start the fault diagnostic procedure.

Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.

B2375


Heat Exchanger Solenoid. Short to B+

Heat Exchanger Solenoid. Open Circuit / Short to Ground


Fault symptoms

Perceived temperature in cabin too high or too low compared to the set temperature.

Conditions

The following conditions apply:


• A short to B+ is indicated when the output for the heat exchanger solenoid is activated and the voltage on pin 24 exceeds 6 V.

• A short to ground is indicated when the output for the circulation pump is not activated and the voltage on pin 24 exceeds 6 V.

• Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.

• The diagnostic trouble code is cleared after the ignition has been turned on 20 times and the malfunction conditions have not been fulfilled.

• When the diagnostic trouble code has been set the output is switched off.