SAAB WIS ONLINE

B2380

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced cabin temperature is too low when compared to the set temperature.

B2380


Circulation Pump. Short to B+

Circulation Pump. Open Circuit / Short to Ground


Fault symptoms

Experienced cabin temperature is too low when compared to the set temperature.

Conditions

The following conditions apply:


A short to B+ is indicated when the output for the circulation pump is activated and the voltage on pin 23 exceeds 6 V.

A short to ground is indicated when the output for the circulation pump is not activated and the voltage on pin 23 exceeds 6 V.

Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.

The diagnostic trouble code is cleared after the ignition has been turned on 20 times and the malfunction conditions have not been fulfilled.

When the diagnostic trouble code has been set the output is switched off.