SAAB WIS ONLINE

B2496

Read the instructions below then start the fault diagnostic procedure.

Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.

B2496


Heater Flap Motor Left. Flap Jammed. Note: May set if not calibrated.





Fault symptoms

Perceived temperature in cabin too high or too low compared to the set temperature.

Conditions

The following conditions apply:


• When the stepping motor operates in the range 10-90 % of its total range (which is 0-100 %), the control module senses if the power consumption is above a certain value, and if this is the case, sets the diagnostic trouble code for jammed flap.

• The diagnostic trouble code can be set if the control module has not been calibrated.

• Continuous monitoring and when calibrating.