SAAB WIS ONLINE

Menu ”Adjustment”

Menu ”Adjustment”

Function Factory setting Alternatives Description
Temperature Zones

TWO

ONE / TWO

One or two zone control can be selected. If one zone control is selected, then the display will always show the same value for the left and right sides. The temperature can be set with the buttons for the right or left sides.

Left Indoor Temperature Increase

0.0°C

-3.0°C -

+3.0°C

The cabin temperature can be increased (or decreased) in relation to the set temperature. A higher value gives a higher cabin temperature in the zone in question.

Right Indoor Temperature Increase

0.0°C

-3.0°C -

+3.0°C

The cabin temperature can be increased (or decreased) in relation to the set temperature. A higher value gives a higher cabin temperature in the zone in question.

Fan Delay

0 s

0-30 s

When there is risk of misting up the windscreen when starting the engine, the control module can delay starting the fan until the evaporator temperature has dropped to a level where any humidity will be absorbed. The fan delay will be active at outside temperatures 0-15°C, 0-20°C with low solar intensity.

Solar Sensor

100

0-255

The value indicates to what degree the solar sensor affects the calculation of the temperature at head height for respective front seat zones. A higher value gives a greater effect.

ACC Will Start In Defrost Below This Temperature

6°C

0-30°C

Cold start. The value indicates below which outside temperature the air distribution starts in defrost position.

Fan Speed Response at New Temperature Setting

30

0-255

The value indicates how much the fan current is temporarily increased if the temperature setting is changed. A higher value gives greater effect.

Automatic Recirculation Below This Speed:

10

0-30 km/h

Extended user-programming. The speed limit for the speed-dependent air recirculation can be adjusted. The value indicates the speed below which air recirculation is selected. Fresh air is selected 20 km/h above this speed.

ECON Below This Temperature

10°C

0-18°C

Extended user-programming. The outside temperature limit for ECON can be adjusted. The value indicates the outside temperature below which ECON is selected. ECON is disengaged 3°C above this temperature.

Parking Heater Temperature Control

AUTOMATIC

AUTOMATIC /100 % HEAT

Parking heater. 100% heat or automatic temperature control can be selected.

Parking Heater Fan Current

6 A

5-10 A

Parking heater. Fan current can be adjusted.

Parking Heater Defroster Duration

25 min

0-60 min

Parking heater. The time during which the control module selects air distribution position defrost can be adjusted. When the time has passed, defrost/floor is selected.

Latest Manual Selection At Ignition On

NO

YES / NO

If YES is selected, then the control module will always select the latest manual setting when the ignition is turned on.

Temperature Defroster to Defroster/Floor on Cold Start

0°C

-10°C -

+10°C

Cold start. The coolant temperature at which air distribution switches from defrost to defrost/floor can be changed in relation to the normal value of 65°C. A higher value means a later switch to defroster/floor.