Combustion chamber
Combustion chamber |
To remove |
1. |
Remove the cover over the combustion air fan.
|
2. |
Remove the four control module bolts.
|
3. |
Carefully extract the control module, unplug the connector and remove the control module from the heater.
|
4. |
Remove the centre housing.
|
5. |
Remove the combustion air fan. Remove the gasket.
|
6. |
Lift out the combustion chamber. Remove the gasket.
|
Installation |
1. |
Make sure that the heat exchanger's O-ring is undamaged and that no leakage has occurred. Change as necessary.
|
2. |
Clean the contact surfaces. Change the gasket and fit the combustion chamber. It can be fitted in only one way.
|
3. |
Change the gasket and fit the combustion air fan. Align the gasket with the three holes.
|
4. |
Fit the centre housing.
|
5. |
Plug connector B2 into the control module.
|
6. |
Fit the control module.
|
7. |
Refit the cover.
|