032
Symptom: Parking heater fails to start.
032 |
Fault symptom
Parking heater fails to start.Condition
Parking heater activated.Diagnostic help
Parking heater can be activated with Tech 2.Parking heater function can be programmed in SID.
Eberspächer diagnostics instrument used for diagnosis.
Diagnostic procedure
1. Check combustion air fan motor
• |
Remove the parking heater.
|
• |
Remove the parking heater control module.
|
• |
Unplug connector B2.
|
• |
Check the fan motor leads for damage.
|
• |
Check that there is no short circuit to ground.
|
• |
Connect an ohmmeter.
|
• |
Take a resistance reading across pin 3 in connector B2 and the heater body.
|
• |
Take a resistance reading across pin 4 in connector B2 and the heater body.
|
Test results OK?
YES |
-
Go to point 2.
NO |
-
Change the fan motor.
-
Go to point 2.
2. Final check
• |
Clear the diagnostic trouble codes in all systems.
|
• |
Contact SID.
|
• |
Activate parking heater (ON).
|
• |
Perform a functionality check.
|
• |
Evaluate the functionality check.
|
• |
Check that the diagnostic trouble code has not recurred.
|
Test results OK?
YES |
-
Fault rectified successfully.
NO |
-
See ’Before changing a control module’.