SAAB WIS ONLINE

Temperature/pressure limits

Temperature/pressure limits

Thermostat, opening temperature

°C(°F)

89 ± 2 (192 ± 4)

System boiling point

°C(°F)

bar

131 (268)

1.4

The temperature gauge goes into the red zone at

°C(°F)

129 ± 2.5 (264 ± 5)

Expansion tank pressure valve, opening pressure

kPa

140 - 150

4-cyl.

Radiator fan, coolant temperature

turn-on, low speed

turn-on, high speed

°C(°F)

100 ± 2 (212 ± 4)

113 ± 2 (235 ± 4)



turn-off, low speed

turn-off, high speed

°C(°F)

96 ± 1 (205 ± 2)

109 ± 1 (228 ± 2)

V6

Radiator fan, coolant temperature

turn-on, low speed

turn-on, high speed

°C(°F)

97 ± 2 (207 ± 4)

107 ± 2 (225 ± 4)

turn-off, low speed

turn-off, high speed

°C(°F)

93 ± 1 (199 ± 2)

103 ± 1 (217 ± 2)