SAAB WIS ONLINE

P1444

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE.

P1444


Canister Close Valve Circuit. Open / Short to Ground.


Fault symptoms


CHECK ENGINE.


On-Board Diagnostics

Type of diagnosis:


- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.


Enable criteria:


- Engine running. Main relay voltage 10 V - 16 V. Output not active.


Fault criteria:


- Voltage below 2V for 1 s.


Dependents:


- None.


System reaction to a fault:


- Fuel adaptation and purging are blocked.


OK report:


- Enable criteria fulfilled. Fault criteria not fulfilled within 60 s.


Fault handling: (See “Fault diagnosis, general” for more information.)


- Type III.


Diagnostic help

Fault diagnosis concerns an electrical fault in the connecting leads or in the valve.

Functions in the diagnostic tool related to the fault:


Activate valve output.


See also the description of activations under ”Fault diagnosis, general” for more information.

Checking the wiring

Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.