P1640
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Engine will not start.
CHECK ENGINE.
Misfiring can occur before trouble code is generated.
Main Relay Circuit. No Voltage to Control Module pin 1.
Fault symptoms
•
|
Misfiring can occur before trouble code is generated.
|
On-Board Diagnostics
Type of diagnosis:
-
|
Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.
|
Enable criteria:
Fault criteria:
-
|
Main relay voltage below 5V for more than 1 s.
|
Dependents:
System reaction to a fault:
OK report:
-
|
Enable criteria fulfilled and fault criteria not fulfilled within 60 s.
|
Fault handling:
(See “Fault diagnosis, general” for more information.)
Diagnostic help
Fault diagnosis concerns electrical fault in connecting leads or in the relay.
Functions in the diagnostic tool related to the fault:
•
|
Main relay voltage, unit V.
|
See also the description of readings in ”Fault diagnosis, general” for more information.
Checking the wiring
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.