EVAP canister purge valve
 
  
 
 
  
   
    
     |  | EVAP canister purge valve | 
   
  
  
  
  
   
    
     
      | 1. | Release the snap-on coupling on the purge hose to the evap canister with tool no. 83 95 261. Press down the brace. 
 
 | 
    
   
  
  
   
    
     
      | 2. | Remove the evap canister purge valve from the bracket. 
 
 | 
    
   
  
  
   
    
     
      | 3. | Carefully twist the evap canister purge valve and unplug the connector. 
 
 | 
    
   
  
  
   
    
     
      | 4. | Loosen the evap canister purge valve from the connecting hose. 
 
 | 
    
   
  
  
  
  
  
  
  
  
   
   
     
   
   
  
  
   
    
     
      | Note | 
     
      | 
        Spray the connector with Kontakt 61( part no. 30 04 520).
        | 
    
   
   
  
  
  
   
    
     
      | 1. | Connect the evap canister purge valve to the connecting hose. 
 
 | 
    
   
  
  
   
    
     
      | 2. | Plug in the evap canister purge valve connector. 
 
 | 
    
   
  
  
   
    
     
      | 3. | Fit the evap canister purge valve to the bracket. 
 
 | 
    
   
  
  
   
    
     
      | 4. | Fit the snap-on coupling on the purge hose to the evap canister. 
 
 |