P1901
Read the instructions below then
start the fault diagnostic procedure.
Symptom: No bus communication with DICE.
No bus communication with DICE. See fault diagnosis 3:5 Bus and diagnostic function.
Fault symptoms
No bus communication with DICE.
Condition
The following conditions are applicable:
Trionic:
•
|
No communication for 10 seconds
|
Diagnostic help
Some of the following symptoms can
perhaps
be observed:
-
|
Diagnostic trouble code P1921 or P1902 in the TCM.
|
-
|
Additional diagnostic trouble codes in the Trionic (P1902, P1923 or P1908).
|
-
|
Radiator fan runs continuously or not at all (coolant may boil).
|
-
|
Direction indicators do not work.
|
-
|
Interior lighting does not work.
|
-
|
Intermittent wiper operation does not work.
|
Checking the wiring harness
Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short-circuits in the leads. Observe the multimeter, test lamp or diagnostic tool during the test.