Vacuum pump, electrically driven
|
Vacuum pump, electrically driven
|
1.
|
Check fuses 11 and 16, making sure they are supplied with current.
|
2.
|
Bypass the pressure switch and make sure the engine starts.
|
3.
|
Check the connectors, wiring harness and ground connections. A diode harness, 372, is connected in series to the pump.
|