Mixed-air temperature sensor, LH
|
Mixed-air temperature sensor, LH
|
1.
|
Remove the lower panel from the driver's side, 3 screws.
|
2.
|
Remove the data link connector, 2 screws, and detach the leads to the floor lighting.
|
3.
|
Pull out the sensor from the air duct running to the lower panel.
|
4.
|
Remove the radio unit and control panel for MCC/ACC.
|
5.
|
Unplug the upper connector (black) from the climate housing.
Withdraw the pins in question from the connector.
|
6.
|
Pull out the sensor.
Note
|
The leads in question are taped on to a wiring harness. Removal can be facilitated by cutting off the leads in question at a suitable place and by using new leads when refitting.
|
|
Fit in reverse order.
Note
|
New leads must be routed when refitting. Fasten the new leads to the original wiring harness.
|