SAAB WIS ONLINE

B2295

Read the instructions below then start the fault diagnostic procedure.

Symptom: Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.

B2295


Heater Flap Motor Right. Flap Loose. Note: May set if not calibrated.





Fault symptoms

Experienced temperature is too low compared to the set temperature. The cabin temperature cannot be adjusted on the right side.

Conditions

The following conditions apply:


When the control module runs the stepping motor towards an end position and the stepping motor continues more than 20% past the expected end position, the diagnostic trouble code for loose flap is set.

The diagnostic trouble code can be set if the control module has not been calibrated.

Continuous monitoring and when calibrating.