B2345

Read the instructions below then start the fault diagnostic procedure.

Symptom: Perceived temperature in cabin too high or too low compared to the set temperature.

B2345


Mixed Air Sensor Right. Short to Ground

Mixed Air Sensor Right. Open Circuit / Short to B+


Fault symptoms

Perceived temperature in cabin too high or too low compared to the set temperature.

Conditions

The following conditions apply:


• Open circuit or short to B+ on pin 18 >4.9 V.

• Short to ground on pin 18<0.1 V.

• Measured every 440 ms and 5 consecutive measurements are required to set a diagnostic trouble code.

• The diagnostic trouble code is deleted after the ignition has been switched on 20 times if the malfunction conditions have not been fulfilled.

• When the diagnostic trouble code is set, the control module uses the default value, which is the relative opening of the air-mixing flap in question multiplied by the coolant temperature.